RIB® BACnet and LonWorks Network Compatible Devices can be hard wired and used instead of more expensive multi-output controllers when a few more control points are needed, and large controllers are too much for the job. They can also be used when control points are widely spread throughout the job site. These devices have been prepackaged to save the installer the time, trouble, and expense of buying separate components and assembling them on the job.
Enclosed LonWorks® Dual I/O Device, One Discrete Output, One Discrete Input, 24 Vac/dc or 120 Vac Power Input
Enclosed LonWorks® Dual I/O Device, One Discrete Output + Override, One Discrete Input, 24 Vac/dc or 120 Vac Power Input
Enclosed LonWorks® Dual I/O Device, One Discrete Output + Override, One Discrete Input (Current Sensor 0.25-20 Amp, Relay Load Sensing)
Enclosed LonWorks® Dual I/O Device, One Discrete Output, One Discrete Input, 24 Vac/dc or 208-277 Vac Power Input
Enclosed LonWorks® Dual I/O Device, One Discrete Output + Override, One Discrete Input, 24 Vac/dc or 208-277 Vac Power Input
Enclosed LonWorks® Dual I/O Device, One Discrete Output + Override, One Discrete Input (Current Sensor 0.25-20 Amp, Relay Load Sensing) 24 Vac/dc or 208-277 Vac Power Input
2.75" Track Mount LonWorks® Dual I/O Device, One Discrete Output + Override, One Discrete Input (Current Sensor 0.25-20 Amp, Relay Load Sensing) 24 Vac/dc or 120 Vac Power Input
2.75" Track Mount LonWorks® Dual I/O Device, One Discrete Output + Override, One Discrete Input (Current Sensor 0.25-20 Amp, Relay Load Sensing) 24 Vac/dc or 208-277 Vac Power Input
Enclosed LonWorks® Three I/O Device, One Discrete Output + Override, One Discrete Input, One Analog Input
4.00" Track Mount LonWorks® Three I/O Device, One Discrete Output + Override, One Discrete Input, One Analog Input
Enclosed LonWorks® Three I/O Device, One Discrete Output + Override, One Discrete Input, Precon Type 2 Thermistor Input
Enclosed LonWorks® Three I/O Device, One Discrete Output + Override, One Discrete Input, Precon Type 3 Thermistor Input
2.75" Track Mount LonWorks® Three I/O Device, One Discrete Output + Override, One Discrete Input, Precon Type 2 Thermistor Input
Enclosed BACnet® MS/TP Network Dual I/O Device, One Binary Output, One Binary Input, 24Vac/dc/120Vac Input
Enclosed BACnet® MS/TP Network Relay Device, One Binary Output, One Binary Input, 24Vac/dc/208-277Vac Input, 208 Vac
Enclosed BACnet® MS/TP Network Relay Device, One Binary Output, Two Binary Inputs (One Current Sensor & One Dry Contact Digital Input), 24 Vac/dc/120 Vac Input
Enclosed BACnet® MS/TP Network Relay Device, One Binary Output, Two Binary Inputs (One Current Sensor Relay Load Sensing & One Dry Contact Digital Input), 24Vac/dc/208-277Vac Input
2.75" Track Mount BACnet® MS/TP Network Relay Device, One Binary Output, Two Binary Inputs (One Current Sensor & One Dry Contact Digital Input), 24Vac/dc/120Vac Input
2.75" Track Mount BACnet® MS/TP Network Relay Device, One Binary Output, Two Binary Inputs (One Current Sensor & One Dry Contact Digital Input), 24Vac/dc/208-277Vac Input
2.75" Track Mount BACnet® MS/TP Network Relay Device, with Binary Output Set Point Function, One Binary Output, Two Binary Inputs, One Analog Input, 24 Vac/dc Power Input
Enclosed BACnet® MS/TP Network Relay Device, with Binary Output Set Point Function, One Binary Output, Two Binary Inputs, One Analog Input
Enclosed BACnet® MS/TP Network Relay Device, One Binary Output + Override, One Binary Input, One Analog Output, One Analog Input
4.00" Track Mount BACnet MS/TP Network Relay Device, Four Binary Outputs, Four Binary Inputs (Dry Contact Binary Inputs), 24 Vac/dc Power Input
2.75" Track Mount BACnet® MS/TP Network Input Device, Twelve Binary Inputs (Voltage or Dry Contacts), with Accumulators
BACnet AHU Fan Safety Alarm and General Purpose Logic Circuit, (6 Alarm Inputs Control Relay 1, 1 GP Input Controls Relay 2), 24Vac/dc Power Input, Standard BACnet RIB 7 BI and 2 BO Relays When Fan Safety Alarm Circuit Disabled.
2.75" Track Mount BACnet® MS/TP Network Input Device, Twelve Binary Inputs (Voltage or Dry Contacts)
Enclosed MODbus® RTU Network Relay Device, One Binary Output, Two Binary Inputs, One Analog Input, 24 Vac/dc Power Input
2.75" Track Mount MODbus® RTU Network Relay Device, One Discrete Output, Two Discrete Inputs, One Analog Input, 24 Vac/dc Power Input